Page 139 - TransAT_Tutorial_Manual
P. 139
TransAT Tutorial Manual 4.1. Dam Break
4.1.5.6 Output Management Tab
• Click Output Management on the left-hand side of the TransATUI
• Set the Output File Format and Frequency of output files from Iteration / timestep
number as follows
Output F i l e Format : Paraview
Frequency of output f i l e s : 50
• Click to select the variables for which data is to be saved
• Activate the following variables in the Output Variables window then click to save the
settings and close the window
Primary Variables :
Pressure : ON
U−Velocity : ON
V−Velocity : ON
Material Properties :
Density : ON
I n t e r f a c e Tracking :
Level−Set : ON
4.1.6 Execute Tab
• Click Execute at the top of the TransATUI.
This tab is where the simulation is started and controlled.
4.1.6.1 Running TransAT
• Click to start the simulation
4.1.7 Visualisation of the results
4.1.7.1 Result files
TransAT creates a folder RESULT to save the results of the simulation:
• xy-dam break.0000000.vtk: Paraview file with initial conditions
• xy-dam break.0001000.vtk: Paraview file after 1000 time steps
c
Ascomp AG Switzerland 129 Version 5.7