Page 292 - TransAT_Tutorial_Manual
P. 292

TransAT Tutorial Manual                                                   7.1. Oilseparation



                       Solid Step Function : ON

                     Phase Average :
                       Phase Volume f r a c t i o n s : ON
                       Phase V e l o c i t i e s : ON

                     Turbulence Modeling :
                       Turbulent Kinetic Energy : ON
                       Turbulent Dissipation Rate : ON
                       Eddy Viscosity Ratio : ON



               7.1.8    Execute Tab
                   • Click Execute at the top of the TransATUI


               This tab is where the simulation is started and controlled.



               Running TransAT
                  The number of processors with which the simulation will be run can be set by modifying
               Number of Processors.

                   • Click    to initialise the flow field from the initialconditions.cxx file.

                   • Click    to start the simulation


               7.1.9    Visualization of the results
               The results of the simulation can be seen with the help of the Open-Source Visualisation Tool,
               ParaView.


                   • To launch ParaView, click Start and select All Programs > ParaView-4.0.1 > ParaView.


                   • Click File − > Open.
                   • Navigate to the project folder.

                   • Go to the RESULT folder and choose <projectname>...vtm for 3D visualization.

                   • Click       .

                   • To only visualize the solid domain, select  in the toolbar (alternatively, select Filters − >
                     Common − > Clip in the toolbar).






                c 
Ascomp AG Switzerland                    282                                  Version 5.7