TransAT Tutorial Manual 2.2. Flow over a group of Buildings
X Min : −75
X Max: 85
Y Min : −100
Y Max: 100
Z Min : 0
Z Max: 70
Now blocks will be split so as to be able to use several processors.
• Select son block by changing the field Select block to 2
• Click then enter the number of blocks in each direction as the following:
X d i r e c t i o n : 1
Y d i r e c t i o n : 2
Z d i r e c t i o n : 1
• Click
BCs Tab
The boundary conditions must now be set for this case. An inflow will be defined on the X
min boundary, and a outflow on the X max. The bottom surface will be defined as a wall. Other
boundaries will be defined as symmetry conditions.
• Select the BCs tab
• Make sure the Inflow BC is available and that its type is Inflow.
• Click to define its parameters.
• In the Basic panel, set the values of the following parameters:
– Inflow Data Source: From BC
– Inflow Type: Velocity based
– Inflow profile: Turbulent
– Inflow Velocity components: u: 1.0 v: 0.0 w: 0.0
• In the Turbulence (RANS) panel, set the values of the following parameters then click
:
– Turbulence intensity: 0.1