Page 67 - TransAT_Tutorial_Manual
P. 67
TransAT Tutorial Manual 2.2. Flow over a group of Buildings
Domain & Grid
• Select the Domain & Grid tab
• Set the following values for the domain boundaries in the Domain section
X min [m] : −200.0 X max [m] : 200.0
Y min [m] : −150.0 Y max [m] : 150.0
Z min [m] : 0.0 Z max [m] : 120.0
• Set the following parameters to define the general properties of the mesh: the number of
cells in each direction domain and the refinement zones of the main grid
Nx: 34 , Cell Ratio : 1.1 , Maximal Ratio : 6
Ny: 41 , Cell Ratio : 1.1 , Maximal Ratio : 6
Nz : 20 , Cell Ratio : 1.2 , Maximal Ratio : 6
• Make sure that Blocks Refinement is selected to give a finer grid around blocks
c
Ascomp AG Switzerland 57 Version 5.7