Page 255 - TransAT_Tutorial_Manual
P. 255

TransAT Tutorial Manual                                                    6.1. Wall Boiling



               Initial Conditions
                  In this tab simple initial conditions can be set.


                   • Select the Initial Conditions tab on the left-hand side of the TransAT user interface
                   • Click Phase 1 in the quantity tree

                   • Set Method to Constant and Value to 0.003

                   • Proceed as above to set the initial state of the remaining quantities as follows
                     Phase 2
                         Method : Constant
                         Value : 0.997

                     U−Velocity
                         Method : Constant
                         Value : 1

                     V−Velocity
                         Method : Constant
                         Value : 0

                     Temperature
                         Method : Constant
                         Value : 345.8
                     Epsilon
                         Method : Automatic
                     TKE
                         Method : Automatic
                     Pressure
                         Method : Constant
                         Value : 0



               Output Management
                  The parameters of the simulation outputs are set in this tab. For this example, only the
               visualization output will be set.

                   • Click Output Management













                c 