Page 320 - TransAT_Tutorial_Manual
P. 320

TransAT Tutorial Manual                                                         7.3. Oilspill



               After clicking   , the Mesh & BCs tab will be opened.

               The Geo, Mesh & BCs, Input and Execute tabs at the top of the TransATUI window can
               now be selected to open the modules to set up a simulation with TransAT.


               7.3.5    Geo

               In this tab, the necessary objects are added to the mesh.

                   • Click Geo at the top of the TransATUI.


               Objects
                  Load the geometry file already prepared and located in the TransAT Object Database.

                   • Select the Database tab.


                   • Expand the Oil-Gas folder

                   • Select oil spill.gts

                   • then click   to load the file to the mesh

                   • In the Choose Units window that popped up, select m in the drop-down box

                   • Activate the check-box Resize Mesh around Geometry to resize the domain


                   • Click    to create the object and send it to the mesh

                   The object properties and boundary conditions must now be defined.

                   • In the object tree (dark grey area), select oil spill.gts.

                   • Enter the following values to set the properties of the objects.
                     Heat Capacity          : 500
                     Thermal Conductivity : 10
                     Density                : 8000
                     Temperature Model      : Conjugate
                     Heat Source            : 0


               The settings will automatically be saved.








                c 
Ascomp AG Switzerland                    310                                  Version 5.7
   315   316   317   318   319   320   321   322   323   324   325