TransAT Tutorial Manual                                                         7.3. Oilspill




                     Name: Outflow
                     Type : Outflow
                     General p r o p e r t i e s :
                       − Outflow Type : Pressure
                       − Outflow Data Source : From I n i t i a l conditions , because
                       the pressure gradient has to be i n i t i a l i s e d .
                     Backflow p r o p e r t i e s :
                       − Backflow Volume Fraction of Phase 2: 1.0
                       − Backflow t o t a l temperature : 277
                     Name: Wall
                     Type : Wall
                     Properties :
                       − Temperature/Heat f l u x choice : Temperature
                       − Temperature/Heat f l u x value : 277

                     Name: Symmetry
                     Type : Symmetry


                   Now a SubBC will be created for the spill inflow:

                   • Select All surfaces in the drop-down list at the top of the BCs tab

                   • With a simple click, highlight YMIN 0 in the surface tree.

                   • Click    to create a subBC. The button is visible next to the other buttons once YMIN 0
                     is selected.
                   • Set the value of Xmin and Xmax as follows: Xmin = -0.25, Xmax = 0.25.


                   • Click