Page 193 - TransAT_Tutorial_Manual
P. 193
TransAT Tutorial Manual 4.5. Spillway
Figure 4.28: Simulation Parameters
Convergence Tolerance : 1e−2
Solver : GMRES
Preconditioner : Block Jacobi
Subpreconditioner : ILU
Max Solver I t e r a t i o n s : 60
Relative Solver Tolerance : 0.01
Initial conditions
It is necessary to initialise the simulation, in order to give the initial location of the different
c
Ascomp AG Switzerland 183 Version 5.7